Chokes & Inductors

Chokes and Inductors are suitable for use in different types of electrical circuits for blocking higher-frequency current (AC) and allowing to pass lower frequency current. There are insulated wires in the form of a coil wisely wound on a magnetic core as to increase the impedance with the frequency. Completely free from flickers, these chokes and inductors are installed in electronic appliances for an optimum voltage standard. In our range of chokes and inductors, we have AC reactor chokes, harmonic mitigation chokes, power line reactors, VFD line & load chokes and DC chokes.


AC Reactor Chokes

AC Reactor Chokes are specially designed for lowering the cable lengths in those applications where the distance from drive to load exceeds 25 meters. Installed on the variable frequency drive, either on its input (line) or output (load) side, these reactor chokes ensure impedance matching, di/dt and harmonic mitigation. Besides this, Ac reactor chokes are also useful in the protection from the noise and surge, transient voltage in the drives. We are also dealing in Export areas like Europe, Africa and Middle East countries

Features :
  • Long functional life
  • Safe to use
  • Sturdy design
  • High performance
  • Ability to reduce the current and voltage stresses on the input rectifier bridge
  • Over-voltage restriction
  • Available in single and three phases
  • Better protection of the drive
  • Improvement of low-frequency conduction emission and sensitivity

Applications :
  • 3%, 5% & 7% Impedance
  • Di / dt Protection Systems
  • 50 Hz to > 5 kHz VFD's
  • Line & Load applications
  • Submersible pumps in oil well
  • Process plants with output (load) chokes
  • VFD's - Yasakawa, Mitsubhishi, Siemens, Allan Bradlley, ABB, Fuji, Danfoss, LG and Control Techniques

AC Reactor Chokes



  Enlarged View


Power Line Reactors

Power Line Reactors, also known as line chokes have their prime importance in controlling the surge current for different loads. These loads include variable frequency drive, thyristor drives, robotic controllers, servo drives and various power electronic modules. In variable frequency drives, the line reactors are used for line and load di /dt protection along with controlling the speed and torque. We are also dealing in Export areas like Europe, Africa and Middle East countries

Features :
  • Oppose rapid changes in current
  • Attenuate spikes of current
  • Limit peak currents
  • Suitable for electronic variable speed drive
  • Extra protection to Ac and DC drives
  • Reduce harmonic distortion in the input line current
  • Ensure no damage to input rectifiers from in-rush current

Applications :
  • Power electronics
  • Variable speed drives of Mitsubhishi. Yasakawa, LG, Danfoss, Control Techniques,¬†Fuji, ABB, Allan Bradlley, Delta and Siemens
  • Thyristor drives
  • Robotic controllers
  • Servo drives

Power Line Reactors



  Enlarged View


Harmonic Mitigation Chokes

Harmonics in an electrical system are very harmful, causing serious damage to the system by reducing the life of equipment and creating heat. In this way, the cable and equipments become stressed, further damaging the equipment. Harmonic Mitigation Chokes are the cost effective solution for minimizing the presence of harmonics in the electrical systems. These are basically available in three phases. In these types of chokes, these is an air gap in between, acting as an integrated choke for an additional inductance and di / dt protection to the load. We are also dealing in Export areas like Europe, Africa and Middle East countries

Features :
  • Reduces the harmonics in electrical systems
  • Available with three phases
  • Ensure extra inductance
  • Di/dt protection to load
  • Reduces operations and maintenance costs
  • Load side surge suppression

Applications :
  • Line & Load applications
  • Di / dt Protection Systems
  • 50 Hz to > 5 kHz VFD's
  • Process plants with output (load) chokes
  • 3%, 5% & 7% Impedance
  • Submersible pumps in oil well
  • VFD's - Yasakawa, Mitsubhishi, Siemens, Allan Bradlley, ABB, Fuji, Danfoss, LG and Control Techniques

Harmonic Mitigation Chokes



  Enlarged View


DC Chokes

Our prudently designed DC Chokes are suitably utilized in industrial machinery power systems for filtering the power supply. These chokes are made sturdily by making use of optimum grade copper wires terminal blocks and electrical steel laminations. To ensure low power loss, the laminations used in these chokes are electrical grade CRGO. This choke range maximizes the circuit inductance in the electric and electronic circuits. We are also dealing in Export areas like Europe, Africa and Middle East countries

Features :
  • Excellent power filtration
  • Make sure no damage to input rectifiers from in-rush current
  • Improvise low frequency conduction emission
  • Overload protection
  • Reduce current-voltage stress
  • Excellent protection to motor drive
  • Lowers harmonic distortion
  • Compacted design

Applications :
  • Power Electronic Systems
  • Rectifier Modules
  • Servo Drives
  • DC Bus Systems
  • Di / dt Smoothening units
  • AC Ripple Reduction Systems

DC Chokes



  Enlarged View


VFD Line & Load Chokes

VFD Line & Load Chokes are offered in different configurations of foot or flange mount with the choice in natural or forced air cooling. Easy to install on the variable frequency drives on both input (line) and output (load) side, these chokes completely ensure the impedance matching, di/dt protection and harmonic mitigation. Using these types of chokes, minimizes the damage to drives caused due to transient voltage, surge currents, and noise. We are also dealing in Export areas like Europe, Africa and Middle East countries

Features :
  • Can be installed on both input and output side of VFD
  • Di/dt protection
  • Offer impedance matching and harmonic mitigation
  • Complete protection to drive from transient voltage, noise and surge currents
  • Lowers the cable length requirement from drive to load
  • Can be foot or flange mounted
  • Option of natural or forced air cooling

Applications :
  • Process plants that require the output (load) chokes
  • Submersible pumps in oil well
  • Line & Load applications
  • VFD's - Yasakawa, Mitsubhishi, Siemens, Allan Bradlley, ABB, Fuji, Danfoss, LG and Control Techniques
  • 50 Hz to > 5 kHz VFD's
  • Process plants with output (load) chokes
  • 3%, 5% & 7% Impedance
  • Di / dt Protection Systems

VFD Line & Load Chokes



  Enlarged View


Automation Trade Fair
Video
Elecrama 2014
Video
Metalex 2013
Video

Top

Product Range
Control Transformers Single Phase Transformer | Custom Designed Transformers | Two Phase Transformers | Three Phase Transformers | EI Lamination & Wound Core Transformers | Import Substitute Transformers
Industrial Transformers Machine Tool Transformers | Elevator Control Transformers | Educational Laboratory Test Transformers | Rectifier Transformers | Textile Machineries Transformers | Universal Voltage Transformers | Marine & Avionic Grade Transformers | Packaging & Pharmaceutical Transformers
Isolation Transformers Magnetic Shielded Isolation Transformers | Multi Combination Delta-Star Transformers | Harmonic Mitigation Transformers | Ultra Isolation Transformers | Split Bobbin Transformers
Chokes & Inductors AC Reactor Chokes | Power Line Reactors | Harmonic Mitigation Chokes | DC ChokesVFD Line & Load Chokes
CE Marked Transformers & Chokes Standard Series Transformers | ECDC with TCF Documentation | Specific Transformers | Booster - Buck Transformers | Multi Secondary Transformers

Member IndiaMART © Procon Controls. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Looking for Product Name ?

534278591